Being one of our best selling products this product has several distinctive features including: Manufacturing: Solaris- New tech, Inc.(USA); For veterinary use. Bright, easy-to-read large LED display; Durable, compact and lightweight.; Accurate, reliable readings during low perfusion and motion; Audible/Visual alarms with adjustable alarm limits, etc.
|
Veterinary Pulse OximeterModel-NT1A-V Features:-
- Manufacturing: Solaris- New tech, Inc.(USA)
- For veterinary use. Bright, easy-to-read large LED display.
- Durable, compact and lightweight.
- Accurate, reliable readings during
low perfusion and motion.
- Audible/Visual alarms with adjustable alarm
limits.
- Can be used for spot-check and continuous monitoring.
- These Veterinary pulse oximeter are suitable for adult, pediatric and neonate.
|  | Send Enquiry |
Table Top Pulse Oximeter with NIBP | Model No:-T Features: - Enhanced SpO2 Accuracy during motion and low perfusion
- Combo display panel-LDC & LED
- Compact bedside configuration
- 72 hours data memory
- Built-in-rechargeable battery
- Adult, pediatric and neonate application
- Probe locking design
- Audible and visual alarm
- RS-232 output (Printer & Communication)
|  | Send Enquiry |
Handheld Pulse OximeterUT100 handheld pulse oximeter is a compact, user-friendly and portable device,measuring the SpO2 and pulse rate in hospital,clinics and homecare, suit for Adult, Pediatric and Neonate. |  | Send Enquiry |
Table Top Pulse Oximeter TM-1309 | Feature:
- Compact and portable, allowing for uninterrupted monitoring with built-in battery.
- High bright LEDS display of NIBP,SPO2 and pulse rate.
- High resolutioncolor LCD for trend tabular and SPO2 waveforms display.
- Manual/auto/continuous measurement of NIBP.
- Adjustable audible and visual alarms.
- Up to 600 groups NIBP data up to 10 hours.
- Suitable for adult, pediatric and neonatal patient.
Display
- 7 segment LEDS for systolic,diastolic,mean pressures,SPO2 and pulse rate.
- 2.4``color LCD for waveforms, bargraphic, trend and aystem menu
NIBP:
- Method:Oscillometry
- Operation modes:Manual/Automatic/STAT
- Auto Measure time :5~250 minutes adjustable,interval 5 minutes
- Measurement range:10~270mmHg
- Overpressure protection:yes
- Resolution:1mmHg
- Alarm:systolic,Diastolic,Mean
SPO2
- Measurement range:0~100%
- Resolution:1%
- Accuracy:70~100% ¡À2%,0~69% unspecified
- Alarm range:0~100%
Pulse Rate:
- Range:0~254bpm
- Resolution:1bpm
- Accuracy: ¡À1bpm
Option: - ECG,Thermal printer
- Dimension:200*230*75mm
- Weight:about 3.5kg
- Power supply:AC 100~250V 50/60Hz
|  | Send Enquiry |
|